The LFPH high-temperature resistant, high-flow-rate pleated Filter Cartridge uses meltblown microfiber modified polyester (PET) as the filter media, with a diameter of 6 mm.
A single 1-inch filter cartridge can have a maximum filtration area exceeding 6m², with a flow rate of up to 60m³/h. It features a stainless steel outer frame, a single-opening design, and...
A specially designed inside-out liquid flow direction ensures that all contaminant particles are trapped inside the filter element. Suitable for power plants.
Oil removal and filtration of high-temperature condensate such as heat network drainage and chemical condensate.
Design parameters
Specifications (diameter * length) | Design flow rate (m³/h) | Maximum flow rate (m³/h) | Filter area (m3) |
6"*20" | 15 | 40 | 3.3 |
6"*40" | 30 | 80 | 6.5 |
6"*60" | 45 | 120 | 8.5 |
Material Structure
model | LFPH |
equipment | PET |
Support/Guide Layer | Modified polyester (PET) |
End cap | Glass fiber reinforced polypropylene |
outer protective sleeve | PET |
Interface type
LFPH | 40 | PET | 0050 | E | S |
LFPH | length | Material | accuracy | sealing ring | Outer ring |
20=20" | PET | 0010 = 1μm | E = EPDM | S = Stainless steel frame | |
40=40" | 0030 = 5μm | S = Silicone rubber | B = PET wrapping tape | ||
60=60" | 0050 = 5μm | F = Fluororubber | S = PBT skeleton | ||
0100 = 10μm | |||||
0150 = 15μm | |||||
0250 = 25μm | |||||
0400 = 40μm | |||||
0700 = 70μm |
Working characteristics
Maximum operating temperature | 120℃ |
Maximum working pressure difference | 0.58 MPa @ 20℃ |
Recommend replacing pressure difference | 0.15Mpa@20℃ |
Typical application scenarios
Power plant heating network drainage |
Chemical condensate |
Other locations for high-temperature condensate filtration |